At present, the main products of Hainice Biotechnology (Dandong) Inc. are blood glucose meters and test strips. The company serves the public with the production concept of "technology is people-oriented and striving for perfection". The product technology is constantly innovated, bringing the gospel of health to the vast number of users.

Forward looking technology research and development

We have a modern 100000 level purification production workshop and a 10000 level inspection environment, with top-notch professional research and development teams conducting forward-looking technology research and productization

Advanced production equipment

Advanced production equipment, scientific monitoring and measurement instruments ensure stable and continuous improvement of product quality

Quality oriented and technological innovation

The company advocates a production philosophy of quality first and technological innovation. Continuously proposing new topics in various stages of production

    Home > Industry News

Test Blood Sugar at Home with HAINICE – Less Blood, Faster Results

Edit date:2026-06-05

Accuracy is the core value of household blood glucose meters and directly determines the effectiveness of health management.
 
Located in Dandong, HAINICE Biotechnology Co., Ltd. is deeply engaged in Class II medical devices, specializing in the R&D and production of blood glucose meters and matched test strips. With fully compliant quality and advanced core technologies, we develop accurate and trustworthy HAINICE blood glucose monitors to guard family health.
As a licensed Class II medical device manufacturer, we strictly abide by China National Standard GB/T19634-2021 and international standard ISO15197:2013, enforcing full-range quality control covering the whole process from R&D to production.
 
Equipped with 4th-generation glucose oxidase biosensor electrode technology, HAINICE blood glucose meters effectively eliminate interferences from vitamin C, maltose and other substances. Its test range covers 1.1–33.3 mmol/L to precisely detect both hypoglycemia and hyperglycemia.
 
Only 0.5μL micro blood sample is needed, together with an adjustable-depth lancing device to minimize pricking pain. Model D shows results in 5 seconds and Model C in 10 seconds for speedy detection.
Humanized design ensures easy operation: Model D adopts code-free automatic identification to avoid human error, and auto-strip ejection prevents cross-contamination.
 
It can store up to 450 sets of test data and calculate average values for 7/14/28/90 days, enabling long-term blood glucose trend tracking.
 
Every HAINICE meter passes stringent quality inspection: test strip inter-batch difference ≤15% and repeatability CV ≤5%, outperforming national standard criteria and realizing high consistency between home test data and clinical hospital detection results.